VECTORLIST - The Mailing List For The Technical Discussion of Vector-Based Arcade Games

December_1999
Re: Tempest Monitor Tech Cause or Symptom???


From: ddhumphr ( )
Date: Thu Dec 09 1999 - 07:27:29 CST


Kurt,

Funny you should say that. I just isolated one of the problems on my G08 to a
ratty mica. "What a pain" doesn't begin to describe the frustration of tearing
it apart 6 times or more!

Ace
Ni-Wumpf Ltd.

Kurt Mahan wrote:

> Are you sure that the mica insulator is doing its job?
>
> I had one that had a crack in it -- what a pain.
>
> Kurt
>
> >
> > I'm trying to fix my Tempest monitor, I've installed a new HV unit, and I
> > powered it up...... no smoke, but a nice flash as F700 vaporized. I tested
> > the transistors connected to it and it appears that the 2N3792 is dead. Is
> > this the cause of my fuse blow or are they both symptoms of a larger
> > problem?? I just wanted some input before I replace the transistor and
> > power it up again, don't want to waste more transistors than I have to.
> > Thanks for all the help in advance!!!! On a positive note, I powered it up
> > without the monitor and from the sounds I'm hearing I think I'll be playing
> > Tempest real soon ;-)
> >
> > Thanks Again,
> > Jeff
> >
> >

--
David Humphrey
Network Consultant
Professional Services

GTE Technology Organization 10 Fawcett St. Cambridge, MA 02138 e-mail: tel: 617 873 7548 Pager: 888 548 5834 ( )